CAMLOG ROOT-LINE 2 Surgical Procedure

16 CAMLOG ® ROOT-LINE 2 IMPLANT PLANNING WITH ORTHOPANTOMOGRAPH/ DENTAL FILM TARGET The target is to specify the implant positions. Now, the final implant plan- ning is performed depending on the selected concept. The x-ray images must show calibrated measurement points to enable measurement of the bone volume available for the implantation. CLINICAL The wax-up or set-up must be checked at the patient. This allows esthetics to be included in the plan, such as the smile line, tooth shade, facial shape and general presentation of the patient. ORTHOPANTOMOGRAM X-Ray planning foils are available in 1.25 : 1 and 1.4 : 1 scales for all implant types to check the dimensions on the orthopantomograph. The foil magni- fications match the delay factors for most orthopantomographs. However, they should be considered only as approximations in implant dimensioning. The self-adhesive implant planning films (X-Ray Transfer pictures, scale 1.25:1) for the specific implant type can be attached to the proposed implant positions on the orthopantomograph film. X-ray transfer pictures on the Orthopantomograph +E219K530090121M +$0000050300MO X-ray planning foil IMPLANT POSITION PLANNING

RkJQdWJsaXNoZXIy MTE0MzMw